{"id":4549,"date":"2021-09-14T10:01:05","date_gmt":"2021-09-14T09:01:05","guid":{"rendered":"https:\/\/quantum-rx.com\/?p=4549"},"modified":"2025-03-14T10:37:49","modified_gmt":"2025-03-14T09:37:49","slug":"z-901-csi-carbon-and-silicon-analyzer","status":"publish","type":"post","link":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/","title":{"rendered":"Z-901 CSi : Carbon and silicon analyzer"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243;]<div id=\"highlighted-text-194598092\" class=\"text-left  vc_custom_1631610418821\"><h3 class=\"text-heading-default\"  data-anim-type=\"\" data-anim-delay=\"0\"><span class=\"pix-highlighted-text  font-weight-normal  heading-font highlighted-text-194598092-0 animate-in\" data-anim-type=\"highlight-grow\" data-anim-delay=\"200\">Carbon and Silicon Analysis<\/span><\/br><\/h3><\/div>[vc_column_text]<strong>The world\u2019s first handheld analyzer to deliver carbon content just got better<\/strong>[\/vc_column_text]<div class=\"d-block w-100 text-left\"><a  href=\"https:\/\/quantum-rx.com\/en\/contact\/\" class=\"btn mb-2    vc_custom_1616923286255  btn-purple d-inline-block      pix-btn-div btn-md\" target=\"_blank\" rel=\"noopener\"    ><span class=\"font-weight-bold \" >Contact us<\/span><\/a><\/div>[\/vc_column][vc_column width=&#8221;1\/2&#8243;]<div class=\"pix-img-div  text-center\"><div class=\"animate-in w-100 d-inline-block\" data-anim-type=\"fade-in\" data-anim-delay=\"0\"><div class=\"tilt\"><div class=\" vc_custom_1708598115164   text-center d-inline-block  w-100 rounded\"  data-jarallax-element=\" \"><img loading=\"lazy\" decoding=\"async\" class=\"card-img2 pix-img-elem rounded  h-1002\" style=\"width:90%;max-height:auto;\" width=\"547\" height=\"700\" srcset=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp 547w, https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI-234x300.webp 234w\" sizes=\"auto, (max-width: 547px) 100vw, 547px\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp\" alt=\"\" \/><\/div><\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]<strong>Why the CSi?<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>Many operators own one or more XRFs for PMI\/NDT. It\u2019s their preferred tool for high temp alloys, and for elements contributing to carbon equivalents (CE), residuals, and stainless steel grades: V, Mn, Cr, Ni, Cu, Nb, Mo. However, XRF does not measure carbon and therefore no carbon equivalents, no separation of L- and H-grade stainless, nor can you use the more forgiving low RE formula (Ni + Cu) &lt; 0.15%. The CSi is the perfect tool for operators who own XRF and need the occasional carbon measurement. It delivers fast, reliable carbon results to complement XRF tests, at a lower cost than the full LIBS system for carbon plus alloys. And SciAps cloud-driven data merging and report generation bring it all together in one report.<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"50%\"><strong>The CSi shows multiple carbon and silicon measurements, and the average. Meets multi-test averaging protocols required by some refineries and pipeline operators.<\/strong><\/td>\n<td width=\"50%\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>SciAps breakthrough LIBS technology is now widely accepted for carbon testing.<\/strong><\/p>\n<p>It\u2019s included in API 578 2nd Edition, it\u2019s accepted at most every major refinery, and in use worldwide by fabricators, pipeline owner\/operators, power plants and other users of carbon steels and L- and H-grade stainless.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4506 aligncenter\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Espace-reduit-Z901-1.png\" alt=\"\" width=\"605\" height=\"403\" srcset=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Espace-reduit-Z901-1.png 605w, https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Espace-reduit-Z901-1-300x200.png 300w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Ultra compact: At 3.5 lbs. (1.6 kg), <\/strong><\/p>\n<p>The CSi rivals the size and weight of most handheld XRF units. It\u2019s the world\u2019s smallest, lightest weight, sleekest analyzer for carbon analysis in alloys.<\/p>\n<p><strong>Cloud-based integration of XRF and CSi data<\/strong><\/p>\n<p>Two analyzers means twice the reporting hassle, right? No. SciAps offers a cloud-based data merge and reporting tool so you can quickly merge CSi and XRF data to produce reports combining carbon and silicon from the LIBS with metals analysis from the XRF. Are you using a different XRF brand? No problem \u2013 ask your supplier for the data structure of their data export and we\u2019ll incorporate it into our SciAps Cloud package. The data structure generally follows an industry standard and doesn\u2019t involve proprietary software.[\/vc_column_text][\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column]<div class=\" \"><div class=\"pix_tabs_container pix-waiting\" data-icons-pos=\"\"><div class=\"nav  nav-pills pix_tabs_btns justify-content-start nav-fill pix-pills-line mb-4 animate-in\" data-anim-type=\"fade-in\" role=\"tablist\" data-anim-delay=\"0\" id=\"v-pills-tab\"  aria-orientation=\"vertical\"><div class=\"nav-item\"><a class=\"nav-link pix-tabs-btn text-24 pix-px-25 py-2 my-2 font-weight-bold\" data-id=\"1615216486827-196b1680-ff35\" role=\"tab\" id=\"pix-tab-btn-1615216486827-196b1680-ff35\" data-toggle=\"pill\" href=\"#pix-tab-1615216486827-196b1680-ff35\"  aria-controls=\"pix-tab-1615216486827-196b1680-ff35\">Documents<\/a><\/div><div class=\"nav-item\"><a class=\"nav-link pix-tabs-btn text-24 pix-px-25 py-2 my-2 font-weight-bold\" data-id=\"1615216258960-cd0f25a5-3780\" role=\"tab\" id=\"pix-tab-btn-1615216258960-cd0f25a5-3780\" data-toggle=\"pill\" href=\"#pix-tab-1615216258960-cd0f25a5-3780\"  aria-controls=\"pix-tab-1615216258960-cd0f25a5-3780\">Features<\/a><\/div><div class=\"nav-item\"><a class=\"nav-link pix-tabs-btn text-24 pix-px-25 py-2 my-2 font-weight-bold\" data-id=\"1615216258961-4c0a8565-6de7\" role=\"tab\" id=\"pix-tab-btn-1615216258961-4c0a8565-6de7\" data-toggle=\"pill\" href=\"#pix-tab-1615216258961-4c0a8565-6de7\"  aria-controls=\"pix-tab-1615216258961-4c0a8565-6de7\">Applications<\/a><\/div><\/div><div class=\"pix_tabs_content animate-in\" data-anim-type=\"fade-in\" data-anim-delay=\"0\"><div class=\"tab-content \"><div class=\"tab-pane  show  \" role=\"tabpanel\" data-toggle2=\"tab\" id=\"pix-tab-1615216486827-196b1680-ff35\" data-bold=\"font-weight-bold\" data-italic=\"\" data-secondary=\"\" data-id=\"1615216486827-196b1680-ff35\" data-icon=\"\" data-title=\"Documents\" aria-labelledby=\"pix-tab-1615216486827-196b1680-ff35\"><div class=\"container\"><div class=\"row justify-content-center\"><div class=\"col bg-white2 rounded-lg2  w-100 m-32 p-42 pix-py-30 col-sm-auto d-md-flex align-items-center text-center text-sm-left justify-content-between2\" style=\"z-index:11;\" ><div class=\"mr-md-5\"><h4 class=\"d-block mr-md-3 mb-md-0 mb-md-0 font-weight-bold text-heading-default text-heading-default\" style=\"font-size:16px;\">Z-901 CSi LIBS Analyzer<\/h4><\/div><div class=\"flex-fill mt-4 mt-sm-0 mt-md-0 text-md-right flex-grow-1\" style=\"min-width:250px;max-width:100%;\"><a  href=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2025\/03\/Sciaps_Z-901-CSi_brochure_En.pdf\" class=\"btn mb-0     btn-outline-purple d-inline-block      btn-normal\"     ><span class=\"font-weight-bold \" >View<\/span><\/a><\/div><\/div><\/div><\/div><div class=\"container\"><div class=\"row justify-content-center\"><div class=\"col bg-white2 rounded-lg2  w-100 m-32 p-42 pix-py-30 col-sm-auto d-md-flex align-items-center text-center text-sm-left justify-content-between2\" style=\"z-index:11;\" ><div class=\"mr-md-5\"><h4 class=\"d-block mr-md-3 mb-md-0 mb-md-0 font-weight-bold text-heading-default text-heading-default\" style=\"font-size:16px;\">QRX-NDT-PMI brochure<\/h4><\/div><div class=\"flex-fill mt-4 mt-sm-0 mt-md-0 text-md-right flex-grow-1\" style=\"min-width:250px;max-width:100%;\"><a  href=\"http:\/\/quantum-rx.com\/wp-content\/uploads\/2018\/11\/QRX-NDT-PMI-Brochure-EN-10-2018-A4-Final.pdf\" class=\"btn mb-0     btn-outline-purple d-inline-block      btn-normal\"     ><span class=\"font-weight-bold \" >View<\/span><\/a><\/div><\/div><\/div><\/div><\/div><div class=\"tab-pane  show  \" role=\"tabpanel\" data-toggle2=\"tab\" id=\"pix-tab-1615216258960-cd0f25a5-3780\" data-bold=\"font-weight-bold\" data-italic=\"\" data-secondary=\"\" data-id=\"1615216258960-cd0f25a5-3780\" data-icon=\"\" data-title=\"Features\" aria-labelledby=\"pix-tab-1615216258960-cd0f25a5-3780\">[vc_column_text]<strong>Weight<\/strong><\/p>\n<p>4.35 lbs. (1.97 kg) with battery<\/p>\n<p><strong>Dimensions<\/strong><\/p>\n<p>10.75 x 2.875 x 8.625 inches<\/p>\n<p><strong>Display<\/strong><\/p>\n<p>2.7-inch high-brightness color touchscreen, readable in all conditions. Rear-facing display for easy results viewing.<\/p>\n<p><strong>Power<\/strong><\/p>\n<p>On board rechargeable Li-ion battery, rechargeable inside device or with external charger, AC power.<\/p>\n<p><strong>Connectivity<\/strong><\/p>\n<p>Built on Google\u2019s Android platform for real-time data exporting, including built-in WiFi (IEEE 802.11b\/g\/n), Bluetooth (BR\/EDR+BLE), GPS and USB-C to connect to virtually any information management system.<\/p>\n<p><strong>Security<\/strong><\/p>\n<p>Password protected. Multi-user support with configurable access.<\/p>\n<p><strong>Regulatory<\/strong><\/p>\n<p>CE, RoHS, USFDA registered.\u00a0Class 3b laser. Sample sensor on board, allows for operation under Class 1 conditions subject to local LSO approval.<\/p>\n<p><strong>Processing Electronics<\/strong><\/p>\n<p>ARM Quad Cortex -A53 1.2GHz memory: 2 GB LPDDR3, 16 GB eMMC<\/p>\n<p><strong>Data Storage<\/strong><\/p>\n<p>Results Storage: 32 GB SD<\/p>\n<p><strong>Spectral range<\/strong><\/p>\n<p>190-420 nm<\/p>\n<p><strong>Calibrations<\/strong><\/p>\n<p>Aluminum: Be, Mg, Al, Si, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Zr, Pb, Bi, Ag, Sn<\/p>\n<p>Titanium Base: Al, Ti, V, Cr, Fe, Cu, Zr, Nb, Mo, Sn<\/p>\n<p>LAS Base: C, Al, Si, Ti, V, Cr, Mn, Fe, Cu, Ni, Nb, Mo, Pb<\/p>\n<p>Stainless Steels: C, Al, Si, Ti, V, Cr, Mn, Ni, Fe, Ni, Cu, Nb, Mo, W<\/p>\n<p>Nickel Base: Al, Si, Ti, Cr, Mn, Fe, Co, Ni, Cu, Nb, Mo, W<\/p>\n<p>Copper Base: Be, Al, Si, Cr, Mn, Fe, Ni, Cu, Zn, Ag, Sn, Pb, Bi<\/p>\n<p>Cobalt Base: Al, Si, Ti, Cr, Mn, Fe, Co, Ni, Cu, Nb, Mo, W<\/p>\n<p>Specialty Bases: Mg, V, Cr, Mn, Co, Zn, Zr, Nb, Mo, Ag, Sn, Hf, Ta, W, Re, Pb, S<\/p>\n<p><strong>Sample Viewing<\/strong><\/p>\n<p>Integrated camera and laser target indicator before and during analysis provide proper sample alignment. Includes 2nd \u201cmacro camera\u201d for scanning QR or barcodes and for photo-documentation and report generation.<\/p>\n<p><strong>Laser Raster<\/strong><\/p>\n<p>On-board Y stage for rastering laser to discrete locations for targeted analysis or averaging.<\/p>\n<p><strong>Atmosphere<\/strong><\/p>\n<p>SciAps proprietary Opti-Purge inert argon environment improves spectral signal-to-noise ratio; improves performance in UV range.<\/p>\n<p><strong>Calibration Check<\/strong><\/p>\n<p>Internal 316 stainless check standard for calibration verification and wavelength scale validation.<\/p>\n<p><strong>Drift Correction<\/strong><\/p>\n<p>On-board automated drift correction software with factory or user-provided reference materials.<\/p>\n<p><strong>Grade Library<\/strong><\/p>\n<p>500+ grades, multi-library support, libraries may be added or edited.[\/vc_column_text]<\/div><div class=\"tab-pane  show  \" role=\"tabpanel\" data-toggle2=\"tab\" id=\"pix-tab-1615216258961-4c0a8565-6de7\" data-bold=\"font-weight-bold\" data-italic=\"\" data-secondary=\"\" data-id=\"1615216258961-4c0a8565-6de7\" data-icon=\"\" data-title=\"Applications\" aria-labelledby=\"pix-tab-1615216258961-4c0a8565-6de7\">[vc_column_text]<\/p>\n<table>\n<thead>\n<tr>\n<td><strong>Model<\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td><strong>Best Application<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Z-901<\/td>\n<td>200 \u2013 420 nm<\/td>\n<td>General alloy testing for scrap sorting, PMI\/NDT or quality assurance. Does not measure carbon.<\/td>\n<\/tr>\n<tr>\n<td>Z-901 CSi<\/td>\n<td>190 \u2013 240 nm<\/td>\n<td>Analyzes carbon and silicon only. The perfect complement to your XRF.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<\/div><\/div><\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; css=&#8221;.vc_custom_1615793074738{padding-top: 30px !important;}&#8221;][vc_row content_placement=&#8221;middle&#8221; pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243; css=&#8221;.vc_custom_1561772161711{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]<div class=\"mb-3 text-left \"><h4 class=\"mb-32 pix-sliding-headline font-weight-bold secondary-font\" data-class=\"secondary-font text-primary\" data-style=\"\">Video demo<\/h4><\/div>[\/vc_column][vc_column width=&#8221;1\/2&#8243;][\/vc_column][\/vc_row][vc_row content_placement=&#8221;middle&#8221; pix_particles_check=&#8221;&#8221; css=&#8221;.vc_custom_1708597571593{padding-right: 10px !important;padding-bottom: 30px !important;padding-left: 10px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h6>Presentation of portable LIBS C901 CSi<\/h6>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;]<div class=\"animate-in d-inline-block2\" data-anim-type=\"fade-in\" data-anim-delay=\"0\"><div class=\"pix-video bg-black rounded-xl  \"  ><img decoding=\"async\" alt=\"Image\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/video-Z901-CSi.webp\" class=\"video-bg pix-opacity-8\" \/><div class=\"pix-video-popup video-play-btn d-flex align-items-center justify-content-center scale shadow-lg bg-white\" style=\"width:100px;height:100px;\" data-aspect=\"embed-responsive-16by9\" data-content=\"&lt;iframe width=&quot;600&quot; height=&quot;400&quot; src=&quot;https:\/\/www.youtube.com\/embed\/WJUezCM7PH4?si=0IAasnvSOJAnfrpr&quot; title=&quot;YouTube video player&quot; frameborder=&quot;0&quot; allow=&quot;accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen&gt;&lt;\/iframe&gt;\" ><span class=\"text-primary\" style=\"height:50px;width:50px;\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 24 24\" ><path d=\"M8 6.82v10.36c0 .79.87 1.27 1.54.84l8.14-5.18c.62-.39.62-1.29 0-1.69L9.54 5.98C8.87 5.55 8 6.03 8 6.82z\"\/><\/svg>\n<\/span><\/div><div class=\"embed-responsive embed-responsive-16by9\"><\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row content_placement=&#8221;middle&#8221; pix_particles_check=&#8221;&#8221; css=&#8221;.vc_custom_1708597571593{padding-right: 10px !important;padding-bottom: 30px !important;padding-left: 10px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h6 id=\"tw-target-text\" class=\"tw-data-text tw-text-large XcVN5d tw-ta\" dir=\"ltr\" data-placeholder=\"Traduction\"><span lang=\"en\">Presentation of the new portable LIBS spectrometer from SciAps, the Z9<\/span><\/h6>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;]<div class=\"animate-in d-inline-block2\" data-anim-type=\"fade-in\" data-anim-delay=\"0\"><div class=\"pix-video bg-black rounded-xl  \"  ><img decoding=\"async\" alt=\"Image\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/03\/Presentation-du-nouveau-spectrometre-LIBS-portable-de-chez-SciAps-le-Z9.png\" class=\"video-bg pix-opacity-8\" \/><div class=\"pix-video-popup video-play-btn d-flex align-items-center justify-content-center scale shadow-lg bg-white\" style=\"width:100px;height:100px;\" data-aspect=\"embed-responsive-16by9\" data-content=\"&lt;iframe width=&quot;600&quot; height=&quot;400&quot; src=&quot;https:\/\/www.youtube.com\/embed\/rW_UCDPbH7E&quot; title=&quot;YouTube video player&quot; frameborder=&quot;0&quot; allow=&quot;accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen&gt;&lt;\/iframe&gt;\" ><span class=\"text-primary\" style=\"height:50px;width:50px;\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 24 24\" ><path d=\"M8 6.82v10.36c0 .79.87 1.27 1.54.84l8.14-5.18c.62-.39.62-1.29 0-1.69L9.54 5.98C8.87 5.55 8 6.03 8 6.82z\"\/><\/svg>\n<\/span><\/div><div class=\"embed-responsive embed-responsive-16by9\"><\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row content_placement=&#8221;middle&#8221; pix_particles_check=&#8221;&#8221; css=&#8221;.vc_custom_1708597585474{padding-right: 10px !important;padding-bottom: 30px !important;padding-left: 10px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h6 id=\"tw-target-text\" class=\"tw-data-text tw-text-large XcVN5d tw-ta\" dir=\"ltr\" data-placeholder=\"Traduction\"><span lang=\"en\">Conference on LIBS at the Industrial Analysis Exhibition co-hosted in part by Quantum RX<\/span><\/h6>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;]<div class=\"animate-in d-inline-block2\" data-anim-type=\"fade-in\" data-anim-delay=\"0\"><div class=\"pix-video bg-black rounded-xl  \"  ><img decoding=\"async\" alt=\"Image\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/03\/Conference-sur-la-LIBS-au-Salon-Analyse-Industrielle-coanime-en-partie-par-Quantum-RX.png\" class=\"video-bg pix-opacity-8\" \/><div class=\"pix-video-popup video-play-btn d-flex align-items-center justify-content-center scale shadow-lg bg-white\" style=\"width:100px;height:100px;\" data-aspect=\"embed-responsive-16by9\" data-content=\"&lt;iframe width=&quot;600&quot; height=&quot;400&quot; src=&quot;https:\/\/www.youtube.com\/embed\/7yLPRelAl8w&quot; title=&quot;YouTube video player&quot; frameborder=&quot;0&quot; allow=&quot;accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen&gt;&lt;\/iframe&gt;\" ><span class=\"text-primary\" style=\"height:50px;width:50px;\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 24 24\" ><path d=\"M8 6.82v10.36c0 .79.87 1.27 1.54.84l8.14-5.18c.62-.39.62-1.29 0-1.69L9.54 5.98C8.87 5.55 8 6.03 8 6.82z\"\/><\/svg>\n<\/span><\/div><div class=\"embed-responsive embed-responsive-16by9\"><\/div><\/div><\/div>[\/vc_column][\/vc_row][\/vc_section][vc_row full_width=&#8221;stretch_row&#8221; pix_particles_check=&#8221;&#8221;][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"[vc_row pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The world\u2019s first handheld analyzer to deliver carbon content just got better[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]Why the CSi? &nbsp; Many operators own one or more XRFs for PMI\/NDT. It\u2019s their preferred tool for high temp alloys, and for elements contributing&#8230;","protected":false},"author":1,"featured_media":5206,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[228],"tags":[],"class_list":["post-4549","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-libs-portable-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Z-901 CSi : Carbon and silicon analyzer - Quantum-Rx<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Z-901 CSi : Carbon and silicon analyzer - Quantum-Rx\" \/>\n<meta property=\"og:description\" content=\"[vc_row pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The world\u2019s first handheld analyzer to deliver carbon content just got better[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]Why the CSi? &nbsp; Many operators own one or more XRFs for PMI\/NDT. It\u2019s their preferred tool for high temp alloys, and for elements contributing...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/\" \/>\n<meta property=\"og:site_name\" content=\"Quantum-Rx\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-14T09:01:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-14T09:37:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"547\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"JLCAdm78\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/\"},\"author\":{\"name\":\"JLCAdm78\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#\\\/schema\\\/person\\\/4a378a421696715e5ae75b47bd4c51dd\"},\"headline\":\"Z-901 CSi : Carbon and silicon analyzer\",\"datePublished\":\"2021-09-14T09:01:05+00:00\",\"dateModified\":\"2025-03-14T09:37:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/\"},\"wordCount\":1490,\"publisher\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/quantum-rx.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Z-901CSI.webp\",\"articleSection\":[\"LIBS Portable\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/\",\"url\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/\",\"name\":\"Z-901 CSi : Carbon and silicon analyzer - Quantum-Rx\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/quantum-rx.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Z-901CSI.webp\",\"datePublished\":\"2021-09-14T09:01:05+00:00\",\"dateModified\":\"2025-03-14T09:37:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/quantum-rx.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Z-901CSI.webp\",\"contentUrl\":\"https:\\\/\\\/quantum-rx.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Z-901CSI.webp\",\"width\":547,\"height\":700},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/libs-en\\\/libs-portable-en\\\/z-901-csi-carbon-and-silicon-analyzer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Z-901 CSi : Carbon and silicon analyzer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/\",\"name\":\"Quantum-RX\",\"description\":\"Advanced Detection Technologies\",\"publisher\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#organization\",\"name\":\"Quantum-RX\",\"url\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/quantum-rx.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/logo-quantum-rx.svg\",\"contentUrl\":\"https:\\\/\\\/quantum-rx.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/logo-quantum-rx.svg\",\"caption\":\"Quantum-RX\"},\"image\":{\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/#\\\/schema\\\/person\\\/4a378a421696715e5ae75b47bd4c51dd\",\"name\":\"JLCAdm78\",\"url\":\"https:\\\/\\\/quantum-rx.com\\\/en\\\/author\\\/jlcadm78\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Z-901 CSi : Carbon and silicon analyzer - Quantum-Rx","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/","og_locale":"en_US","og_type":"article","og_title":"Z-901 CSi : Carbon and silicon analyzer - Quantum-Rx","og_description":"[vc_row pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The world\u2019s first handheld analyzer to deliver carbon content just got better[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]Why the CSi? &nbsp; Many operators own one or more XRFs for PMI\/NDT. It\u2019s their preferred tool for high temp alloys, and for elements contributing...","og_url":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/","og_site_name":"Quantum-Rx","article_published_time":"2021-09-14T09:01:05+00:00","article_modified_time":"2025-03-14T09:37:49+00:00","og_image":[{"width":547,"height":700,"url":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp","type":"image\/webp"}],"author":"JLCAdm78","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/#article","isPartOf":{"@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/"},"author":{"name":"JLCAdm78","@id":"https:\/\/quantum-rx.com\/en\/#\/schema\/person\/4a378a421696715e5ae75b47bd4c51dd"},"headline":"Z-901 CSi : Carbon and silicon analyzer","datePublished":"2021-09-14T09:01:05+00:00","dateModified":"2025-03-14T09:37:49+00:00","mainEntityOfPage":{"@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/"},"wordCount":1490,"publisher":{"@id":"https:\/\/quantum-rx.com\/en\/#organization"},"image":{"@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/#primaryimage"},"thumbnailUrl":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp","articleSection":["LIBS Portable"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/","url":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/","name":"Z-901 CSi : Carbon and silicon analyzer - Quantum-Rx","isPartOf":{"@id":"https:\/\/quantum-rx.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/#primaryimage"},"image":{"@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/#primaryimage"},"thumbnailUrl":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp","datePublished":"2021-09-14T09:01:05+00:00","dateModified":"2025-03-14T09:37:49+00:00","breadcrumb":{"@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/#primaryimage","url":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp","contentUrl":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Z-901CSI.webp","width":547,"height":700},{"@type":"BreadcrumbList","@id":"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-csi-carbon-and-silicon-analyzer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/quantum-rx.com\/en\/"},{"@type":"ListItem","position":2,"name":"Z-901 CSi : Carbon and silicon analyzer"}]},{"@type":"WebSite","@id":"https:\/\/quantum-rx.com\/en\/#website","url":"https:\/\/quantum-rx.com\/en\/","name":"Quantum-RX","description":"Advanced Detection Technologies","publisher":{"@id":"https:\/\/quantum-rx.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/quantum-rx.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/quantum-rx.com\/en\/#organization","name":"Quantum-RX","url":"https:\/\/quantum-rx.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/quantum-rx.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2024\/02\/logo-quantum-rx.svg","contentUrl":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2024\/02\/logo-quantum-rx.svg","caption":"Quantum-RX"},"image":{"@id":"https:\/\/quantum-rx.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/quantum-rx.com\/en\/#\/schema\/person\/4a378a421696715e5ae75b47bd4c51dd","name":"JLCAdm78","url":"https:\/\/quantum-rx.com\/en\/author\/jlcadm78\/"}]}},"_links":{"self":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/posts\/4549","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/comments?post=4549"}],"version-history":[{"count":0,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/posts\/4549\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/media\/5206"}],"wp:attachment":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/media?parent=4549"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/categories?post=4549"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/tags?post=4549"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}