{"id":4586,"date":"2021-09-15T10:22:27","date_gmt":"2021-09-15T09:22:27","guid":{"rendered":"https:\/\/quantum-rx.com\/?page_id=4586"},"modified":"2021-09-15T14:20:43","modified_gmt":"2021-09-15T13:20:43","slug":"sciaps-libs-analyzer-models","status":"publish","type":"page","link":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/","title":{"rendered":"SciAps LIBS Analyzer Models"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; css=&#8221;.vc_custom_1631695912651{background-color: #f8f9fa !important;}&#8221;][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]We offers four differents hardware platforms with our handheld LIBS analyzers.<\/p>\n<p>From sophisticated analysis of ultra-low elemental concentrations in alloys, ores, brines and powders, to basic material or scrap sorting, we offers a specific model for your application.[\/vc_column_text][\/vc_column][\/vc_row][\/vc_section][vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; pix_visibility=&#8221;1&#8243; css=&#8221;.vc_custom_1631709636478{padding-top: 20px !important;padding-bottom: 80px !important;background-color: #ffffff !important;}&#8221; b_custom_height=&#8221;100px&#8221; el_id=&#8221;pix_section_features&#8221;][vc_row pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243;]<a href=\"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-901-analyzer\/\" target=\"_blank\"><div id=\"1615899386385-a092c086-a7e8\" class=\"text-left  vc_custom_1631709759926\"><h3 class=\"font-weight-bold  secondary-font text-primary \" style=\"\"  >Z-901<\/h3><div class=\"text-body-default      \" style=\"padding-top:10px;\"  >The Z-901 features an all-new ergonomic design, a 0.5 lb. weight reduction down to about 3.5 lbs. (1.6 kg), improved heat dissipation, and completely updated software and processing electronics.<br \/>\nThe Z-901 also leads the way featuring the first-ever \u201cdual burn\u201d technology. Users can test with the 901 either using an \u201cair burn\u201d method or using argon-purge for applications requiring higher precision and lower limits of detection.<br \/>\nThe Z-901 uses a single spectrometer to cover the wavelength range of 200 \u2013 440 nm. It is factory calibrated for a suite of 15-20 elements, depending on the application. Or operators may use the accompanying ProfileBuilder software package to customize to specific elements, their own calibration standards, and spectral processing. The Z-901 can be setup to measure the emissions of any element EXCEPT Li, Na, H, C, N, O, Cl, Br, F, Ce, Rb, S. Common factory-calibrated applications include alloy, mining and environmental analysis, typically for beryllium in soil.<\/div><\/div><\/a>[\/vc_column][vc_column width=&#8221;1\/2&#8243;]<a href=\"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z901-csi-analyzer\/\" target=\"_blank\"><div id=\"1615899386387-23ac8fb4-f23d\" class=\"text-left  vc_custom_1631709768981\"><h3 class=\"font-weight-bold  secondary-font text-primary \" style=\"\"  >Z-901 CSi<\/h3><div class=\"text-body-default      \" style=\"padding-top:10px;\"  >The \u201cCSi\u201d is a dedicated unit for measuring carbon and silicon in steels and stainless. It is the ideal tool if you own handheld XRF units and want to continue to use those for measuring common alloy elements such as Cr, V, Mn, Ni, Cu, Mo, Nb, etc. but need the occasional carbon and\/or silicon measurement. The CSi opens up a very cost-effective option for many NDT professionals that have older XRF units and may only want to add in C and Si measurements in order to determine carbon equivalents (CE), verify L versus H-grade stainless or include a carbon measurement with low RE steels.<\/div><\/div><\/a>[\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243;]<a href=\"https:\/\/quantum-rx.com\/en\/libs-en\/libs-mobile-en\/z-902-carbon-analyzer\/\" target=\"_blank\"><div id=\"1631696193925-ac839a7e-d573\" class=\"text-left  vc_custom_1631709784574\"><h3 class=\"font-weight-bold  secondary-font text-primary \" style=\"\"  >Z-902 C<\/h3><div class=\"text-body-default      \" style=\"padding-top:10px;\"  >The Z-902 \u201cC\u201d is a dedicated NDT\/PMI analyzer for carbon content and a wide range of alloys and alloy bases. It features 2 spectrometers (instead of one in the 901) to extend the spectral range down to 190 nm with high resolution, specifically to measure carbon content in steels, stainless and other alloys. The Z-902 is the analyzer of choice globally for the measuring carbon content in alloys, and carbon equivalents. It is also factory calibrated for a suite of 15-20 elements in 7 common alloy bases: aluminum, steel, stainless, nickel, cobalt, titanium and copper bases. Additional bases or calibrations may be added by the factory or the user.<\/div><\/div><\/a>[\/vc_column][vc_column width=&#8221;1\/2&#8243;]<a href=\"https:\/\/quantum-rx.com\/en\/libs-en\/libs-portable-en\/z-903-libs-analyzer\/\" target=\"_blank\"><div id=\"1631696193927-fb1cb808-3042\" class=\"text-left  vc_custom_1631709794171\"><h3 class=\"font-weight-bold   text-primary \" style=\"\"  >Z-903<\/h3><div class=\"text-body-default      \" style=\"padding-top:10px;\"  >Analyzes every element in the periodic table.<br \/>\nThe Z-903 is the LIBS of choice for applications in geochem, mining, oil &#038; gas. It is our 3-spectrometer system, spanning a wavelength range of 190 nm \u2013 950 nm. This range allows for the entire periodic table to be analyzed including critical elements such as S, H, the halogens and others. Like the other Z, the Z-903 is factory calibrated for specific applications in mining and environmental applications. Examples include lithium in brines and hard rock, beryllium, boron and carbon analysis, fluorine, and sodium in soils or other materials. Operators may also use the accompanying PC software to set up their own calibrations for a variety of material types \u2013 glasses, polymers, archaeological and forensics samples, and many others.<\/div><\/div><\/a>[\/vc_column][\/vc_row][\/vc_section][vc_row pix_particles_check=&#8221;&#8221;][vc_column css=&#8221;.vc_custom_1631696383339{padding-top: 40px !important;}&#8221;][vc_column_text css=&#8221;.vc_custom_1631696366592{padding-top: 20px !important;}&#8221;]<\/p>\n<h3 style=\"text-align: center;\"><strong>Quick Model Guide<\/strong><\/h3>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]<\/p>\n<table width=\"92%\">\n<tbody>\n<tr>\n<td width=\"16%\"><strong>Model<\/strong><\/td>\n<td width=\"21%\"><strong>Spectrometer Range (nm)<\/strong><\/td>\n<td width=\"24%\"><strong>Elements Measurable<\/strong><\/td>\n<td width=\"30%\"><strong>Applications<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"16%\"><strong>Z-901<\/strong><\/td>\n<td width=\"21%\">200 \u2013 440<\/td>\n<td width=\"24%\">Common elements for most applications including light elements Be, B. Excludes C, Li, Na,<\/td>\n<td width=\"30%\">Air-burn and argon purge for alloy analysis, mining and environmental, general analytical studies.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\"><strong>Z-901 CSi<\/strong><\/td>\n<td width=\"21%\">190 \u2013 240<\/td>\n<td width=\"24%\">C and Si<\/td>\n<td width=\"30%\">Dedicated to measuring C, Si in steels, stainless and (future) Ni alloys.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\"><strong>Z-902 Carbon<\/strong><\/td>\n<td width=\"21%\">190 \u2013 440<\/td>\n<td width=\"24%\">Elemental range of the Z-901 plus carbon.<\/td>\n<td width=\"30%\">Targets carbon measurements in alloys, plus other alloy bases. Includes a high resolution spectrometer \u00a0measurement of carbon in alloys including L-grade stainless.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\"><strong>Z-902 +<\/strong><\/td>\n<td width=\"21%\">190 \u2013 625<\/td>\n<td width=\"24%\">Analysis of the Z-901 but extends spectral range to include Li, Na and C.\u00a0 Carbon is for non-alloy applications.<\/td>\n<td width=\"30%\">Extends analytical range to include Li in alloys, ores and brines, non-alloy measurement of C, and Na. \u00a0<strong>Not for carbon in steels, stainless or other alloys.<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"16%\"><strong>Z-903<\/strong><\/td>\n<td width=\"21%\">190 \u2013 950<\/td>\n<td width=\"24%\">Above plus H, N, O, Cl, F, Br, Ce, Rb and S.<\/td>\n<td width=\"30%\">Mostly for geochem, researchers, academic institutions, forensics or specific analytical applications.\u00a0 Measures emissions of every element through transuranics.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1631712031775{padding-top: 60px !important;}&#8221;]<\/p>\n<h3 style=\"text-align: center;\"><strong>Uniquely SciAps Product Features<\/strong><\/h3>\n<p>&nbsp;<\/p>\n<p><strong>Spectrometer<\/strong><\/p>\n<p>The Z-900 Series uses a patented stack-spectrometer design that delivers wide wavelength range and high resolution \u2013 superior to any other handheld LIBS. Depending on your application, the 900 Series can be purchased with 1-3 spectrometers.\u00a0 The 3-spectrometer Z-903 range is 190 nm \u2013 950 nm. In addition to the elements measured by the Z-902, this wider wavelength range also measures: H, F, Br, Cl, N, O, S, Rb, Cs and K.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Camera\/Video<\/strong><\/p>\n<p>The SciAps Z-900 Series offers dual cameras.\u00a0 A wide-area lens \u201cmacro-camera\u201d provides for photo-documentation of samples tested and can read bar codes or QR codes for sample identification.\u00a0 The internal camera allows pinpoint viewing and aiming of the laser for sample analysis. The internal \u00a0camera augments the power of LIBS analysis. The laser is automatically focused to &lt; 100 \u00b5m beam size, without requiring any external, intensity-killing collimation commonly found with XRF. The Z\u2019s camera can be used to precisely strike many types of samples. Welds can be analyzed in multiple locations when examining weld chemistry changes across the weld. The Z\u2019s camera can hone-in on particular regions for non-homogenous samples. Images are automatically saved with results for photo-documentation. And, the Android platform enables sharing of the data and high resolution images when collaborating with colleagues or reporting results.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Laser<\/strong><\/p>\n<p>The key to good LIBS analysis is creating a good plasma. The best plasma\u2019s come from the highest power densities on the sample. The Z\u2019s PULSAR laser technology fires laser pulses in the 5-6 mJ\/pulse range, at up to 50 Hz frequencies, with 1 ns wide pulses. It is well established that mJoule, rather than micro-joule laser pulses yield superior analytical results.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Data Sharing &amp; Connectivity<\/strong><\/p>\n<p>The Z is built on Google\u2019s Android Platform and offers compatibility and connectivity to smartphones, tablets and other devices via the Android SHARE feature.\u00a0 It\u2019s also available with Cloud-based data sharing, data merging between multiple instrument platforms, and report generation.\u00a0 It avoids the tedious process of downloading and importing data \u2013 including the Android SHARE feature. The powerful processor offers Wireless, Bluetooth communications and is GPS enabled.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>No Fragile X-Ray Detectors<\/strong><\/p>\n<p>Unlike XRF analyzers, there\u2019s no sensitive detector element near the front window. The Z uses a virtually impenetrable \u201ctough as Pyrex\u201d quartz window. Because LIBZ collects light in the visible and ultraviolet spectral region, rather than x-ray region, a durable, thick window may be used so long as it\u2019s transparent to visible and UV light. Light traverses this quartz window, then into a well-protected spectrometer. You will not be able to break this detector window!<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text css=&#8221;.vc_custom_1631697921008{border-top-width: 20px !important;border-bottom-width: 20px !important;padding-top: 60px !important;padding-bottom: 60px !important;}&#8221;]<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4582 alignleft\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png\" alt=\"\" width=\"286\" height=\"756\" srcset=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png 286w, https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor-113x300.png 113w\" sizes=\"auto, (max-width: 286px) 100vw, 286px\" \/><\/p>\n<p><strong>Auto Calibration<\/strong><\/p>\n<p>The Z monitors time and internal temperature, and automatically institutes a calibration as needed. This means no cal-check samples to carry around (and lose or get dirty). Reduces the likelihood of operator error by automating the calibration procedure.<\/p>\n<p><strong>Battery<\/strong><\/p>\n<p>The newly designed Z uses much less power, and lasts 6+ hours on a single, lightweight battery. Plug in the AC adapter to recharge and power the analyzer. External battery charger and spare battery included<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4584\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/sciaps2.png\" alt=\"\" width=\"605\" height=\"97\" srcset=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/sciaps2.png 605w, https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/sciaps2-300x48.png 300w, https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/sciaps2-600x97.png 600w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4588\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Sciaps-software.png\" alt=\"\" width=\"605\" height=\"282\" srcset=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Sciaps-software.png 605w, https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Sciaps-software-300x140.png 300w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \/><\/p>\n<p><strong>Empirical Apps<\/strong><\/p>\n<p>Generate all your own calibrations using our Profile Builder software package[\/vc_column_text][\/vc_column][\/vc_row][vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; pix_visibility=&#8221;1&#8243; css=&#8221;.vc_custom_1592707565829{padding-top: 80px !important;padding-bottom: 80px !important;background-color: #ffffff !important;}&#8221; b_custom_height=&#8221;100px&#8221;][vc_row pix_particles_check=&#8221;&#8221;][vc_column width=&#8221;1\/2&#8243;]<div class=\"d-inline-block \" ><div class=\"   text-left d-inline-block  w-100 rounded-0\"  ><img loading=\"lazy\" decoding=\"async\" class=\"card-img2 pix-img-elem rounded-0  h-1002\" style=\"height:auto;\" width=\"399\" height=\"485\" srcset=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Onebox-1.png 399w, https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Onebox-1-247x300.png 247w\" sizes=\"auto, (max-width: 399px) 100vw, 399px\" src=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Onebox-1.png\" alt=\"\" \/><\/div><\/div>[\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3><strong>X-ray and laser together in \u201cOne Box\u201d<\/strong><\/h3>\n<p>&nbsp;<\/p>\n<p>The SciAps X and Z make the perfect complement for elemental analysis. The X analyzes transition and heavy metals with great precision, and is ideal for bulk sample types like alloys, soils, liquids, powders. The Z is ideal for low atomic number elements like Li, Be, B, C, Na, F even down to hydrogen. And the Z, with it\u2019s integrated targeting camera and 100 um beam spot, is better suited for micro-analysis. The One-Box delivers optimal analysis across all elements and sample types, for bulk analysis or micro-analysis.<\/p>\n<p>The X and Z also operate on the same battery, use the same charger and other accessories.[\/vc_column_text][\/vc_column][\/vc_row][\/vc_section][vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; css=&#8221;.vc_custom_1631695912651{background-color: #f8f9fa !important;}&#8221;][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]<\/p>\n<h3 style=\"text-align: center;\"><strong>SciAps Z \u2013 Top 10 Advantages<\/strong><\/h3>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>The ONLY LIBS that offers Dual-Burn Operation<\/strong><\/p>\n<p>The Z features on-board argon purge for high precision analysis. Users may also run the Z in air-burn if your testing requires less precision or you have restrictions on gas canisters. 50 years of spark optical emission have proven the analytical superiority of argon purge!<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Protect your Confidential Materials Chemistry<\/strong><\/p>\n<p>The Z includes desktop\/tablet software allowing a user (password protected) to modify calibrations, elements analyzed, grade IDs and various spectral pre-processing. Customers can keep their proprietary materials proprietary!<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Lightest, Fastest LIBS Analyzer<\/strong><\/p>\n<p>The latest Z is the lightest, fastest high performance LIBS analyzer. Perfectly balanced, you can test fatigue-free all day long. Wrist strap also included. Results shown in 1 second, full test time 3 sec.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>No Grinding, except for Carbon<\/strong><\/p>\n<p>The Z uses a 50 Hz laser, \ufb01ring 10 surface cleaning shots in 0.2 seconds to burn away surface contaminants, dirt, etc. The Z is the only LIBS unit proven to analyze even the dirtiest scrap without grinding.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Beam Rastering<\/strong><\/p>\n<p>The Z rasters the laser to 6 different positions and automatically averages the results. Why do this? Because LIBS lasers are typically 50 um in diameter, and testing a single location may not average out inhomogeneities even in vacuum melt alloys. Also if the laser happens to hit an inclusion or embedded contaminant, an outlying result will be averaged out over the rastering. 50 years of LIBS scientific literature tell you that rastering is a \u201cmust have.\u201d<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Free Software Upgrades<\/strong><\/p>\n<p>Software upgrades free for the life of the analyzer.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Customer Flexibility<\/strong><\/p>\n<p>Do you have specific UI or SW requests? Tell us about them. Most requests are requested by multiple customers, and we\u2019ll always do our best to include them in a future software update.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>On-board Camera, WiFi, Bluetooth and GPS<\/strong><\/p>\n<p>Photo-document samples, and\/or aim laser at specific area on sample if needed. WiFi\/BT make for easy data transfer and connectivity. USB connections also included.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Vibrant Display<\/strong><\/p>\n<p>Brightest, largest display, easiest to read in direct sunlight.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Service Costs<\/strong><\/p>\n<p>Generally the lowest in the industry. Why?\u00a0 Products are designed for rough use and low lifetime service costs. SciAps makes theirs own lasers and spectrometers, so we can repair items on a component-level.<\/p>\n<p>&nbsp;[\/vc_column_text][\/vc_column][\/vc_row][\/vc_section]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"[vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; css=&#8221;.vc_custom_1631695912651{background-color: #f8f9fa !important;}&#8221;][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]We offers four differents hardware platforms with our handheld LIBS analyzers. From sophisticated analysis of ultra-low elemental concentrations in alloys, ores, brines and powders, to basic material or scrap sorting, we offers a specific&#8230;","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-4586","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SciAps LIBS Analyzer Models - Quantum-Rx<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SciAps LIBS Analyzer Models - Quantum-Rx\" \/>\n<meta property=\"og:description\" content=\"[vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; css=&#8221;.vc_custom_1631695912651{background-color: #f8f9fa !important;}&#8221;][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]We offers four differents hardware platforms with our handheld LIBS analyzers. From sophisticated analysis of ultra-low elemental concentrations in alloys, ores, brines and powders, to basic material or scrap sorting, we offers a specific...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/\" \/>\n<meta property=\"og:site_name\" content=\"Quantum-Rx\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-15T13:20:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/\",\"url\":\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/\",\"name\":\"SciAps LIBS Analyzer Models - Quantum-Rx\",\"isPartOf\":{\"@id\":\"https:\/\/quantum-rx.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png\",\"datePublished\":\"2021-09-15T09:22:27+00:00\",\"dateModified\":\"2021-09-15T13:20:43+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#primaryimage\",\"url\":\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png\",\"contentUrl\":\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/quantum-rx.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SciAps LIBS Analyzer Models\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/quantum-rx.com\/en\/#website\",\"url\":\"https:\/\/quantum-rx.com\/en\/\",\"name\":\"Quantum-RX\",\"description\":\"Advanced Detection Technologies\",\"publisher\":{\"@id\":\"https:\/\/quantum-rx.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/quantum-rx.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/quantum-rx.com\/en\/#organization\",\"name\":\"Quantum-RX\",\"url\":\"https:\/\/quantum-rx.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/quantum-rx.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2024\/02\/logo-quantum-rx.svg\",\"contentUrl\":\"https:\/\/quantum-rx.com\/wp-content\/uploads\/2024\/02\/logo-quantum-rx.svg\",\"caption\":\"Quantum-RX\"},\"image\":{\"@id\":\"https:\/\/quantum-rx.com\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SciAps LIBS Analyzer Models - Quantum-Rx","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/","og_locale":"en_US","og_type":"article","og_title":"SciAps LIBS Analyzer Models - Quantum-Rx","og_description":"[vc_section full_width=&#8221;stretch_row&#8221; pix_over_visibility=&#8221;&#8221; css=&#8221;.vc_custom_1631695912651{background-color: #f8f9fa !important;}&#8221;][vc_row pix_particles_check=&#8221;&#8221;][vc_column][vc_column_text]We offers four differents hardware platforms with our handheld LIBS analyzers. From sophisticated analysis of ultra-low elemental concentrations in alloys, ores, brines and powders, to basic material or scrap sorting, we offers a specific...","og_url":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/","og_site_name":"Quantum-Rx","article_modified_time":"2021-09-15T13:20:43+00:00","og_image":[{"url":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/","url":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/","name":"SciAps LIBS Analyzer Models - Quantum-Rx","isPartOf":{"@id":"https:\/\/quantum-rx.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#primaryimage"},"image":{"@id":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#primaryimage"},"thumbnailUrl":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png","datePublished":"2021-09-15T09:22:27+00:00","dateModified":"2021-09-15T13:20:43+00:00","breadcrumb":{"@id":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#primaryimage","url":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png","contentUrl":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2021\/09\/Libs-sensor.png"},{"@type":"BreadcrumbList","@id":"https:\/\/quantum-rx.com\/en\/sciaps-libs-analyzer-models\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/quantum-rx.com\/en\/"},{"@type":"ListItem","position":2,"name":"SciAps LIBS Analyzer Models"}]},{"@type":"WebSite","@id":"https:\/\/quantum-rx.com\/en\/#website","url":"https:\/\/quantum-rx.com\/en\/","name":"Quantum-RX","description":"Advanced Detection Technologies","publisher":{"@id":"https:\/\/quantum-rx.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/quantum-rx.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/quantum-rx.com\/en\/#organization","name":"Quantum-RX","url":"https:\/\/quantum-rx.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/quantum-rx.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2024\/02\/logo-quantum-rx.svg","contentUrl":"https:\/\/quantum-rx.com\/wp-content\/uploads\/2024\/02\/logo-quantum-rx.svg","caption":"Quantum-RX"},"image":{"@id":"https:\/\/quantum-rx.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/pages\/4586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/comments?post=4586"}],"version-history":[{"count":0,"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/pages\/4586\/revisions"}],"wp:attachment":[{"href":"https:\/\/quantum-rx.com\/en\/wp-json\/wp\/v2\/media?parent=4586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}